How much do you know about air-conditioner installation

by:Jingeao     2020-04-28

series of air-conditioner who buy the supermarket customer all know, the large-scale freezers need to install, not like ordinary freezers, plugged in, according to the instruction manual use directly. Because as the industry development needs, air-conditioner compressor, management, installation is tricky. If built-in compressor, it is relatively simple, cabinets. If the external compressor, it is need a installation personnel to the above services. Take the air-conditioner pipeline installation below as an example to share experience. Air-conditioner pipeline connection must be no dust, moisture to enter, in order to avoid jams refrigeration system to malfunction, and the house so tightly connected with the installation of the pipe joint should be reliable, operation should be completed within five minutes, don't allow the connection pipeline operation and go do something else. Indoor, outside the unit connection pipe is too long, or air-conditioner refrigeration capacity will drop, heat preservation and heat insulation must each piping of the instrument and the trachea, if fluid tube in contact with the trachea, heat transfer, will affect the cooling system pressure and refrigerating capacity decreased, some things can also cause the compressor overheating caused failure. Second during the installation process, we consider the distance of air transport, heat preservation effect, and so on. So in pipeline processing installation process must not be pressed flat steel pipe, if the cooling tube flattening, deformation or fracture can make the refrigeration flow resistance or must leak. Air-conditioner pipeline damage, must change with the same diameter of pipe, otherwise it will affect the normal use of air-conditioner, if the trachea is too thick, refrigerant flow too slow affect oil return, and trachea pipe too hours, will influence the refrigerating capacity of the air-conditioner pipeline resistance is too high, fluid pipe, pipe diameter is too small will cause the same pipe resistance, influence the refrigerating capacity. of gas pipeline and liquid pipeline cannot meet the, if the thick tube and a tube, can make the refrigerant flow chaos, freezers in abnormal motions, noise and condenser water or ice. Indoor machine drain cannot raise in midflight, are not allowed to have the height of the slope to the outdoor, adding more does not allow the drain on ventilation tube. Buildings by drains, should not be concave part, in case the drain is blocked, condensate direct emissions to freezers, waterways or drains, shall be made in a drain on a water seal ring, prevent odor or drain smell will arrange a drain to indoor, indoor air pollution. These are freezers during the installation process, need to pay attention to matters, know these, can more quickly complete the installation process.


Ningbo Jingeao Electronics Co., Ltd also discusses implications for both research and the practice of operations in building systems to help people succeed in both the short and long run.
Visit Ningbo Jingeao Electronics Co., Ltd for the best in supplies: Jingeao Electronics.
Ningbo Jingeao Electronics Co., Ltd always think about our customer first. To determine what the consumers would want out of their relationship on social, and work from there.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: